Slide 1
Slide 2
Slide 3
Slide 4
Slide 5
Slide 6
Slide 7
Slide 8
Slide 9
Slide 10
Slide 11
Slide 12
Slide 13
Slide 14
Slide 15
Slide 16
Product List
Shown here is the lab data using a pair of HMC1048 mixers as the I and Q mixers. The LO was provided by a pair of ADF4355 PLLs and a pair of HMC451 RF amplifiers were used as LO buffers. With a single mixer in a traditional signal chain, the IF resulting from the UI was measured at ~ -12 dBm (see the peak of the curve above). At 90 degrees of phase shift between the I and Q LO sources, the IF resulting from the UI was measured at ~ -38 dBm, so an image rejection of about 26 dB.
PTM Published on: 2016-09-27