The choice of an RMS responding detector will generally begin with a narrowing down of the available options based on the required input frequency or input frequency range. The second most important specification will be the power detection range of the device which can range from 30dB to 65dB. The final device selection can then be made based on temperature stability, power consumption and package size.
PTM Published on: 2010-12-10